PowerCharger DUAL and QUAD OWNER’S MANUAL
8 Priority Battery Function A unique operating feature of all PowerChargers allows the operator to select any battery on any charge position as a PR
9 The standard test is adequate for virtually all conditions to verify the capacity of the battery before taking it into the field. The 24 hour tes
10 When testing is completed, the LCD Main Display will indicate “TEST DONE”. To display or print test results: 1. Press the DISPLAY button on the
11 OPERATION AS DC CAMERA SUPPLY FROM MAINS Each PowerCharger model can operate cameras and camcorders using the four pin camera output connector l
12 POWER LOSS MEMORY MODE The PowerCharger features a special Power Loss Memory or “Power Down” mode. When mains power is interrupted while batteri
13 WARRANTY IMPORTANT: PLEASE MAIL WARRANTY REGISTRATION CARD WITHIN TEN (10) DAYS OF PURCHASE. We must have this card on file at our SERVICE DEPA
TABLE OF CONTENTS INTRODUCTION ... 1 STANDARD FEATURES.
1 INTRODUCTION This Anton/Bauer InterActive 2000 PowerCharger represents over 25 years of Anton/Bauer technology and experience in a totally new por
2 IMPORTANT NOTICE READ ALL INSTRUCTIONS, NOTES AND OPERATING SPECIFICATIONS FULLY BEFORE OPERATING THIS EQUIPMENT.
3 SAFEGUARDS Power Sources: This unit was designed to operate at mains voltages from 90 to 250 Volts AC, 50-60 Hz. Risk of Electrical Shock: Refer
4 Charging As with all Anton/Bauer chargers, charging with an InterActive 2000 PowerCharger is fully automatic. Mount any applicable battery to any
5 Three Stage Charging Methodology In general, the PowerCharger will deliver a three stage charge routine to each battery. 1. Stage One will delive
6 1 - - - - - - - 2 - - - - - - - LCD Indications Each PowerCharger’s liquid crystal display (LCD) will display the status of each battery, as well
7 LED Indications Each charge position of a PowerCharger has a pair of LEDs (one red, one green) which indicate the status of the battery attached t